Review Question Answers
Answer: A. Spin echo is the only dark blood imaging technique. Steady State Free Precession, TruFISP, and Fast Gradient Echo are all bright blood techniques. 2) Which of the following techniques is used to null myocardium for delayed enhancement imaging? Answer: C. Inversion recovery pulses are used to null signal from normal myocardium to make areas with delayed enhancement more visible. 3) Which of the following is useful for volumetric measurements of ventricular size and mass? Answer: C. Steady state free precession images show a clear border between the myocardium and the blood pool that is essential for performing volumetric measurements. |